Technical Grade
AAAC 6201 CONDUCTOR

AAAC 6201 CONDUCTOR

Aluminum Alloy 6201 Wires, concentrically stranded over a central wire of Aluminum 6201. Conductor(AAAC) have been widely used in power transmission lines with various voltage levels, and also used in power lines across great rivers, heavy ice area, and other places special geographical characteristics LEAVE MESSAGE SEND E-MAIL

CategoryOverhead Bare Conductor
SourceQZ Cable Group

Product Images

Product Overview

Application

AAAC is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is also suitable for laying through basins, rivers and valleys where there are special geographic features.

Standard

​American Standard-ASTM B 399/B 399M German Standards-DIN 48201-6 British Standards-BS EN 50182 BS 3242 International Electrotechnical Commission International Standards&China National Standards-IEC 61089 GB/T 1179 Russian National Standard-AAAC GOST 839-80

Technical Parameters

ASTM B 399/B 399M Full Size

Code NameAreaSize&Stranding ACSR with equal diameterNo. And diameter of wiresCable diameterWeightRated StrengthStrand Length
NominalActual
MCMmm²AWG or MCMAI/SteelmmmmKg/kmkNm±5%
Akron30.5815.4866/17/1.685.0442.74.923000
Alton48.6924.7146/17/2.126.3568.07.843000
Ames77.4739.2226/17/2.678.0210812.452000
MORE
Azusa123.362.381/06/17/3.3710.1117218.972000
Ananeim155.478.652/06/17/3.7811.3521723.933000
Amherst195.799.223/06/17/4.2512.7527330.182500
Alliance246.9125.14/06/17/4.7714.3134538.052000
Butte312.8158.6266.826/719/3.2616.3043748.763000
Canton394.5199.9336.426/719/3.6618.3055158.912500
Cairo465.5235.8397.526/719/3.9819.8865069.482000
Darien559.5283.547726/719/4.3621.7978183.522000
Elgin652.4330.6556.526/719/4.7123.5491197.421500
Flint740.8375.363626/737/3.5925.161035108.213000
Greely927.2469.879526/737/4.0228.141295135.472500

ASTM B 399/B 399M Reduced Size

Nominal sectionStrandingOverall diameterWeightRated StrengthConductive ResistanceCapacity
AWG&MCMmm^2No.×mmmmkg/kmKNΩ/KmA
613.27/1.554.6536.24.182.536169
421.17/1.965.8857.96.691.58693
233.57/2.477.419210.60.9987123
MORE
1/053.57/3.129.36146.8170.62592165
2/067.37/3.5010.5184.820.40.49738190
3/084.97/3.9311.7923325.70.3945219
4/01077/4.4213.26294.732.50.31188253
25012619/2.9114.55346.738.80.26509280
30015219/3.1915.95416.746.60.22059313
35017819/3.4517.25487.3520.1886345
40020319/3.6918.45557.559.50.16486375
45022819/3.9119.5562666.80.14683402
50025319/4.1220.669574.20.13224429
55027937/3.1021.7766.283.90.11995455
60030337/3.2322.61831.9910.11049478
65033037/3.3723.59905.594.90.1015504
70035437/3.4924.43971.21010.09464525
75038137/3.6225.3410451090.08796549
80040437/3.7326.1111091160.08285569
90045637/3.9627.7212501310.07351612
100050837/4.1829.2613931460.06597653
125063161/3.6332.6717321790.05306743
150075961/3.9835.8220822150.04414827
175088661/4.3038.724312510.03781904

AAAC 6201 ASTM B 399

Conductor sizeSectional AreaStrandingDiameter of Complete ConductorWeightRated StrengthDC Resistance @ 20°CCurrent Capacity
No. of Aluminium WiresIndividual wire diameter@ 75°C@ 85°C
(kcmil)(mm²)(No.)(mm)(mm)(Kg/Km)KN(Ω/Km)(Ampere)(Ampere)
1439.2729613.935.119992070.04597693897
1348.8685613.7834.0218781940.04893671865
MORE
1259.6638613.6532.8517511810.05248646831
1165.1590613.5131.5916201670.05675620794
1077.4547613.3830.4215021560.0612595760
927.2470374.0228.1412891350.07133547694
740.8375373.5925.1310281070.08944482607
652.4331194.7123.55908.3970.1012449564
559.5284194.3621.8778.383.10.1181412514
465.4236193.9819.9648.669.20.1417371461
394.5200193.6618.3548.558.60.1676337417
312.8159193.2616.3435.146.50.2112295362
246.912574.7714.31343.237.80.2678256313
195.799.374.2512.75272.5300.3373224272
155.478.673.7811.34215.623.80.4264195236
123.362.473.3710.11171.318.90.5365170205
77.4739.272.678.01107.512.40.8547129154
48.6924.772.126.3667.87.831.35698116
30.5815.571.685.0442.584.922.1597488
1750886614.338.724312510.037817671002
1500759613.9835.8220822150.04414708918
1250631613.6332.6717321790.05306642826
1000508374.1829.2613931460.06597571727
900456373.9627.7212501310.07351538682
800404373.7326.1111091160.08285503636
750381373.6225.3410451090.08796487613
700354373.4924.43971.21010.09464467587
650330373.3723.59905.594.90.1015449563
600303373.2322.61831.9910.11049428535
550279373.121.7766.283.90.11995408510
500253194.1220.669574.20.13224386480
450228193.9119.5562666.80.14683364451
400203193.6918.45557.559.50.16486340421
350178193.4517.25487.3520.1886315388
300152193.1915.95416.746.60.22059287353
250126192.9114.55346.738.80.26509258316
211.610774.4213.26294.732.50.31188234285
167.884.973.9311.7923325.70.3945204247
133.167.373.510.5184.820.40.49738178215
105.653.573.129.36146.8170.62592155187
66.3633.572.477.419210.60.9987118140
41.7421.171.965.8857.96.691.58689106
26.2413.271.554.6536.24.182.53616779

All Aluminum Alloy Conductor (AAAC) Cables DIN 48201-6

Nominal AreaStrandingOverall DiameterWeightRated StrengthElectrical ResistanceCurrent Rating*
NominalTeorical
mm^2mm^2No.×mmmmkg/kmKNΩ/KmA
1615.897/1.705.1434.442.074278
2524.257/2.106.3666.771.3593102
3534.367/2.507.5949.60.9591126
MORE
5049.487/3.00913513.820.666158
5048.3519/1.80913313.50.6849156
7065.8119/2.1010.518118.380.5032189
9593.2719/2.5012.525626.050.3551234
120116.9919/2.801432232.680.2831269
150147.1137/2.2515.840641.090.2256309
185181.6237/2.5017.550050.730.1828352
240242.5461/2.2520.367067.740.1371420
300299.4361/2.5022.582783.630.111477
400400.1461/2.89261104111.760.0831568
500499.8361/3.2329.11379139.60.0665649
625626.291/2.9632.61732174.90.0531742
800802.0991/3.3536.92218224.020.0415857
1000999.7191/3.7441.12767279.220.0333971

AAAC cable BS EN 50182 BS 3242

CodeStrandingNominal AreaSectional AreaOverall DiameterWeightRated StrengthElectrical ResistanceCurrent Rating*
No.×mmmm^2mm^2mmkg/kmKNΩ/KmA
Box7/1.851518.85.5551.45.551.74887
Acacia7/2.082023.86.2464.97.021.3828101
Almond7/2.342530.17.0282.28.881.0926116
MORE
Cedar7/2.543035.57.6296.810.460.9273129
Deodar7/2.773542.28.31115.212.440.7797143
Fir7/2.954047.88.85130.614.110.6875155
Hazel7/3.305059.99.9163.417.660.5494178
Pine7/3.616071.610.83195.621.140.4591199
Holly7/3.917084.111.73229.524.790.3913219
Willow7/4.047589.712.1224526.470.3665228
7/4.198096.5212.5726427.170.3411245
7/4.4490108.013.3229830.650.3023260
Oak7/4.6580118.913.95324.535.070.2767272
19/2.82100118.7014.132633.420.2787290
Mulberry19/3.18125150.915.9414.344.520.2192314
Ash19/3.48150180.717.4496.153.310.183351
Elm19/3.7617521118.8579.262.240.1568386
Poplar37/2.87200239.420.09659.470.610.1387416
37/3.05225270.3021.3574476.080.1227448
Sycamore37/3.23250303.222.61835.289.40.1095480
Upas37/3.53300362.124.71997.5106.820.0917535
Walnut37/3.81350421.8026.671162118.720.07860584
Yew37/4.0640047928.421319.6141.310.0693633
Totara37/4.14425498.128.981372.1146.930.0666648
Rubus61/3.50500586.931.51622173.130.0567714
Sorbus61/3.71600659.433.391822.5194.530.0505764
Araucaria61/4.14700821.137.262269.4242.240.0406868
Redwood61/4.56800996.241.042753.2293.880.0334970

AAAC Cables IEC 61089 A2 A3 Conductors GB/T 1179

CodeA2/A3 Sectional AreaA2/A3 StrandingA2/A3 Overall DiameterA2/A3 WeightA2/A3 Rated StrengthElectrical ResistanceCurrent Rating*
mm^2No.×mmmmkg/kmKNΩ/KmA
1618.4/18.67/1.83/1.845.49/5.5250.4/50.85.43/6.041.789686
2528.8/29.07/2.29/2.306.87/6.9078.7/79.58.49/9.441.1453113
4046/46.57/2.89/2.918.67/8.72125.9/127.113.58/15.100.7158151
MORE
6372.5/73.27/3.63/3.6510.89/10.90198.3/200.221.39/23.060.4545200
100115/11619/2.78/2.7913.9/14.0316.3/319.333.95/37.760.2877266
125144/14519/3.10/3.1215.5/15.6395.4/399.242.44/47.200.2302305
160184/18619/3.51/3.5317.55/17.60506.1/511.054.32/58.560.1798355
200230/23219/3.93/3.9519.65/19.70632.7/638.767.91/73.200.1439407
250288/29019/4.39/4.4121.95/22.1790.8/798.484.88/91.500.1151466
315363/36637/3.53/3.5524.71/24.80998.9/1008.4106.95/115.30.0916535
400460/46537/3.98/4.0027.86/28.001268.4/1280.5135.81/146.400.0721618
450518/52337/4.22/4.2429.54/29.701426.9/1440.5152.79/164.700.0641663
500575/58137/4.45/4.4731.15/31.301585.5/1600.6169.76/183.000.0577706
560645/65161/3.67/3.6933.03/33.201778.4/1795.3190.14/204.960.0516755
630725/73261/3.89/3.9135.01/35.202000.7/2019.8213.9/230.580.0458809
710817/82561/4.13/4.1537.17/37.32254.8/2276.2241.07/259.860.0407866
800921/93061/4.38/4.4039.42/39.62540.6/2564.8271.62/292.800.0361928
9001036/104691/3.81/3.8341.91/42.102861.1/2888.3305.58/329.400.0321992
10001151/116291/4.01/4.0344.11/44.403179/3209339.53/3660.02891051
11201289/130191/4.25/4.2746.75/46.93560.5/3594.4380.27/409.920.02581118
1250143991/4.4949.393973.7424.410.02311185

AAAC Conductor, Type Ah, All Aluminium Alloy Conductor (GOST 839-80)

Nominal Cross SectionCalculated Cross SectionNumber of iresConductor DiameterDC Resistance at 20Min. Breaking LoadConductor Weight
mm2mm2mmΩNkg/km
1615.975.11.9037373443
2524.976.41.2139537068
3534.377.50.8819738994
MORE
5049.5790.612110662135
12011719140.260925186321
1501481915.80.205931900406
185182.31917.50.166939386502

AAAC Conductor, Type Ankp, All Aluminium Alloy Conductor (GOST 839-80)

Nominal Cross SectionCalculated Corss SectionNumber of WiresConductor DiameterDC Resistance at 20Min. Breaking LoadConductor WeightGrease Weight
mm2mm2mmΩNkg/kmkg/km
1615.975.11.90373734430.5
2524.976.41.21395370680.5
3534.377.50.88197389940.5
MORE
5049.5790.612110662135
12011719140.260925186321
1501481915.80.205931900406
185182.31917.50.1669

Scroll horizontally to review complete specification columns.

Request Full TDS

Structure & Technical Illustration

AAAC 6201 CONDUCTOR

Aluminum Alloy 6201 Wires, concentrically stranded over a central wire of Aluminum 6201. Conductor(AAAC) have been widely used in power transmission lines with various voltage levels, and also used in power lines across great rivers, heavy ice area, and other places special geographical characteristics LEAVE MESSAGE SEND E-MAIL

Product image and technical reference.

Related Products

AAC 1350 CONDUCTOR

AAC 1350 CONDUCTOR

View Details
AAAC 1120 CONDUCTOR

AAAC 1120 CONDUCTOR

View Details
ACSR CONDUCTOR

ACSR CONDUCTOR

View Details
ACSR/AW/AS CONDUCTOR

ACSR/AW/AS CONDUCTOR

View Details