Application
Messenger Wire, Overhead Ground or Static Wire, Guy Wire, Stay Wire,Zinc-Coated (Galvanized) Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR),Zinc coated steel wires, Galfan Steel Wire
Non-rusting, high-strength guys wire for electrical distribution and transmission lines, communications and signal lines, antenna towers, masts, stacks, and other structures
Messenger Wire, Overhead Ground or Static Wire, Guy Wire, Stay Wire,Zinc-Coated (Galvanized) Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR),Zinc coated steel wires, Galfan Steel Wire
| Approx.Strand Dia. | Number of Wires/Dia. | Siemem Martin Grade | High Strength Grade | Extra-high Strength Grade | Approx.Weight | |
| Inch | mm | KN | KN | KN | kg/km | |
| 7/32 | 5.56 | 3/2.64 | 10.409 | 15.569 | 21.796 | 131 |
| 1/4 | 6.35 | 3/3.05 | 13.523 | 21.04 | 29.981 | 174 |
| 1/4 | 6.35 | 3/3.05 | – | – | – | 174 |
| 9/32 | 7.14 | 3/3.30 | 15.035 | 23.398 | 33.362 | 204 |
| 5/16 | 7.94 | 3/3.68 | 18.193 | 28.246 | 40.479 | 256 |
| 3/8 | 9.52 | 3/4.19 | 24.732 | 37.187 | 52.489 | 328 |
| 1/8 | 3.18 | 7/1.04 | 4.048 | 5.916 | 8.18 | 49 |
| 5/32 | 3.97 | 7/1.32 | 6.539 | 9.519 | 13.078 | 76 |
| 3/16 | 4.76 | 7/1.57 | 8.452 | 12.677 | 17.748 | 108 |
| 3/16 | 4.76 | 7/1.65 | – | – | – | 118 |
| 3/16 | 5.56 | 7/1.83 | 11.387 | 17.126 | 24.02 | 145 |
| 7/32 | 6.35 | 7/2.03 | 14.012 | 21.129 | 29.581 | 181 |
| 1/4 | 7.14 | 7/2.36 | 18.905 | 28.469 | 39.812 | 243 |
| 9/32 | 7.94 | 7/2.64 | 23.798 | 35.586 | 49.82 | 305 |
| 5/16 | 7.94 | 7/2.77 | – | – | – | 335 |
| 3/8 | 9.52 | 7/3.05 | 30.915 | 48.04 | 68.503 | 407 |
| 7/16 | 11.11 | 7/3.68 | 41.591 | 64.499 | 92.523 | 594 |
| 1/2 | 12.7 | 7/4.19 | 53.823 | 83.627 | 119.657 | 768 |
| 9/16 | 14.29 | 7/4.78 | 69.837 | 108.981 | 155.688 | 991 |
| 5/8 | 15.88 | 7/5.26 | 84.961 | 131.667 | 188.605 | 1211 |
| 1/2 | 12.7 | 19/2.54 | 56.492 | 84.961 | 118.768 | 751 |
| 9/16 | 12.49 | 19/2.87 | 71.616 | 107.202 | 149.905 | 948 |
| 5/8 | 15.88 | 19/3.18 | 80.513 | 124.995 | 178.819 | 1184 |
| 3/4 | 19.05 | 19/3.81 | 116.543 | 181.487 | 259.331 | 1719 |
| 7/8 | 22.22 | 19/4.50 | 159.691 | 248.211 | 354.523 | 2352 |
| 1/1 | 25.4 | 19/5.08 | 209.066 | 325.61 | 464.839 | 2384 |
| 1/1 | 25.4 | 37/3.63 | 205.508 | 319.827 | 456.832 | 3061 |
| 11/8 | 28.58 | 37/4.09 | 262 | 407.457 | 581.827 | 4006 |
| 11/4 | 31.75 | 37/4.55 | 324.72 | 505.318 | 721.502 | 4833 |
| Number of wires/Dia. | Approx.Strand Dia. | Minimum Breaking Load of Strand | Approx. Weight | ||||||
| Grade 350 | Grade 480 | Grade 700 | Grade 850 | Grade 1000 | Grade 1150 | Grade 1300 | |||
| mm | kN | kN | kN | kN | kN | kN | kN | kg/km | |
| 3/1.80 | 3.9 | 2.65 | 3.66 | – | – | – | – | – | 60 |
| 3/2.65 | 5.7 | 5.8 | 7.95 | – | – | – | – | – | 130 |
| 3/3.25 | 7 | 8.7 | 11.95 | – | – | – | – | – | 195 |
| 3/4.00 | 8.6 | 13.2 | 18.1 | – | – | – | – | – | 295 |
| 4/1.80 | 4.4 | 3.55 | 4.9 | – | – | – | – | – | 80 |
| 4/2.65 | 6.4 | 7.7 | 10.6 | – | – | – | – | – | 172 |
| 4/3.25 | 7.9 | 11.6 | 15.9 | – | – | – | – | – | 260 |
| 4/4.00 | 9.7 | 17.6 | 24.1 | 35.2 | – | – | – | – | 390 |
| 5/1.50 | 4.1 | 3.1 | 4.24 | 6.18 | – | – | – | – | 69 |
| 5/1.80 | 4.9 | 4.45 | 6.1 | 8.9 | – | – | – | – | 95 |
| 5/2.65 | 7.2 | 9.65 | 13.25 | 19.3 | – | – | – | – | 220 |
| 5/3.25 | 8.8 | 14.5 | 19.9 | 29 | – | – | – | – | 320 |
| 5/4.00 | 10.8 | 22 | 30.15 | 43.95 | – | – | – | – | 490 |
| 7/0.56 | 1.7 | 0.6 | 0.83 | 1.2 | – | 1.7 | 1.98 | 2.24 | 14 |
| 7/0.71 | 2.1 | 0.97 | 1.33 | 1.94 | – | 2.75 | 3.19 | 3.6 | 28 |
| 7/0.85 | 2.6 | 1.39 | 1.9 | 2.8 | – | 3.95 | 4.57 | 5.15 | 31 |
| 7/0.90 | 2.7 | 1.55 | 2.14 | 3..1 | – | 4.45 | 5.12 | 5.8 | 35 |
| 7/1.00 | 3 | 1.92 | 2.64 | 3.85 | – | 5.5 | 6.32 | 7.15 | 43 |
| 7/1.25 | 3.8 | 3.01 | 4.1 | 6 | – | 8.55 | 9.88 | 11.15 | 67 |
| 7/1.40 | 4.2 | 3.75 | 5.17 | 7.54 | 9.16 | 10.75 | 12.35 | 14 | 84 |
| 7/1.60 | 4.8 | 4.9 | 6.75 | 9.85 | 11.95 | 14.1 | 16.2 | 18.3 | 110 |
| 7/1.80 | 5.4 | 6.23 | 8.55 | 12.45 | – | 17.8 | 20.5 | 23.2 | 140 |
| 7/2.00 | 6 | 7.7 | 10.55 | 15.4 | – | 22 | 25.3 | 28.6 | 170 |
| 7/2.36 | 7.1 | 10.7 | 14.7 | 21.4 | – | 30.6 | 35.2 | 39.8 | 240 |
| 7/2.65 | 8 | 13.5 | 18.5 | 27 | – | 38.6 | 44.4 | 50.2 | 300 |
| 7/3.00 | 9 | 17.3 | 23.75 | 34.65 | – | 49.5 | 56.9 | 64.3 | 392 |
| 7/3.15 | 9.5 | 19.1 | 26.2 | 38.2 | – | 54.55 | 62.75 | 70.9 | 430 |
| 7/3.25 | 9.8 | 20.3 | 27.85 | 40.65 | – | 58.05 | 66.8 | 75.5 | 460 |
| 7/3.65 | 11 | 25.6 | 35.15 | 51.25 | – | 73.25 | 84.2 | 95.2 | 570 |
| 7/4.00 | 12 | 30.9 | 42.2 | 61.6 | – | 88 | 101 | 114 | 690 |
| 7/4.25 | 12.8 | 34.75 | 47.65 | 69.5 | – | 99.3 | 114 | 129 | 780 |
| 7/4.75 | 14 | 43.4 | 59.45 | 86.8 | – | 124 | 142.7 | 161.3 | 970 |
| 19/1.00 | 5 | 5.22 | 7.16 | 10.45 | – | 14.92 | 17.16 | 19.4 | 120 |
| 19/1.25 | 6.3 | 8.16 | 11.19 | 16.32 | – | 23.32 | 26.81 | 30.31 | 180 |
| 19/1.40 | 7 | 10.24 | 14.04 | 20.47 | – | 29.25 | 33.64 | 38.02 | 230 |
| 19/1.60 | 8 | 13.37 | 18.35 | 26.75 | – | 38.2 | 43.93 | 49.66 | 300 |
| 19/2.00 | 10 | 20.9 | 28.65 | 41.78 | 50.74 | 59.69 | 68.64 | 77.6 | 470 |
| 19/2.50 | 12.5 | 32.65 | 44.8 | 65.29 | 79.28 | 93.27 | 107.3 | 121.3 | 730 |
| 19/3.00 | 15 | 47 | 64.5 | 94 | 114.1 | 134.3 | 154.5 | 174.6 | 1050 |
| 19/3.55 | 17.8 | 65.8 | 90.27 | 131.6 | 159.9 | 188 | 216.3 | 244.5 | 1470 |
| 19/4.00 | 20 | 83.55 | 114.6 | 167.1 | 203 | 238.7 | 274.6 | 310.4 | 1870 |
| 19/4.75 | 23.8 | 117.85 | 161.4 | 235.7 | 286 | 336.7 | 387.2 | 437.7 | 2630 |
Scroll horizontally to review complete specification columns.
Request Full TDSNon-rusting, high-strength guys wire for electrical distribution and transmission lines, communications and signal lines, antenna towers, masts, stacks, and other structures
Product image and technical reference.