Application
zinc–5 % aluminummischmetal (Zn–5Al–MM) alloy-coated, steel core wire for use in Overhead Electrical Conductors. ACSS ACSS/TW The high temperature low sag solution
Zinc-5%Aluminum mischmetal alloy galvanized steel wire is used for Power Transmission and Distribution Line Hardware,Slope protection、Undersea optical cable armoured with low carbon galvanized steel wire,Overhead Electrical Conductors.
zinc–5 % aluminummischmetal (Zn–5Al–MM) alloy-coated, steel core wire for use in Overhead Electrical Conductors. ACSS ACSS/TW The high temperature low sag solution
operates continuously at high temperatures up to 250°C, with proper steel coating, ensuring maximum utilization and performance; standard coating for high temperature operation is a Zn-5% Al Mischmetal coating so that customers can take full advantage of the 250°C continuous operating temperature rating. Galvanized coatings are rated only 180°C for continuous operation.
| Specified Diameter of Coated Wire,mm | Area Density of Coating, min, oz/ft 2 of Uncoated Wire Surface | ||
| Class A | Class B | Class C | |
| 0.0500 to 0.0599, incl | 0.60 | 1.20 | 1.80 |
| 0.0600 to 0.0749, incl | 0.65 | 1.30 | 1.95 |
| 0.0750 to 0.0899, incl | 0.70 | 1.40 | 2.10 |
| 0.0900 to 0.1039, incl | 0.75 | 1.50 | 2.25 |
| 0.1040 to 0.1199, incl | 0.80 | 1.60 | 2.40 |
| 0.1200 to 0.1399, incl | 0.85 | 1.70 | 2.55 |
| 0.1400 to 0.1799, incl | 0.90 | 1.80 | 2.70 |
| 0.1800 to 0.1900, incl | 1.00 | 2.00 | 3.00 |
| Specified Diameter, in. | Stress at 1 % Extension, min, Ksi | Ultimate Tensile Strength, min, MPa | Elongation in 250 mm, min, % | ||||||
| Class A | Class B | Class C | Class A | Class B | Class C | Class A | Class B | Class C | |
| 1.60 to 2.30, incl | 190 | 180 | 170 | 210 | 200 | 190 | 3.0 | 3.0 | 3.0 |
| Over 2.30 to 3.05, incl | 185 | 175 | 165 | 205 | 195 | 185 | 3.5 | 3.0 | 3.0 |
| Over 3.05 to 3.60, incl | 180 | 170 | 160 | 205 | 195 | 185 | 4.0 | 3.0 | 3.0 |
| Over 3.60 to 4.80, incl | 170 | 160 | 155 | 200 | 185 | 180 | 4.0 | 4.0 | 4.0 |
| Specified Diameter of Coated Wire, mm | Area Density of Coating, min.g/m2 of Uncoated Wire Surface | |
| Class A | Class C | |
| 1.27 to 1.52, incl | 183 | 549 |
| 1.53 to 1.90, incl | 198 | 594 |
| 1.91 to 2.28, incl | 214 | 642 |
| 2.29 to 2.64, incl | 229 | 687 |
| 2.65 to 3.04, incl | 244 | 732 |
| 3.05 to 3.55, incl | 259 | 777 |
| 3.56 to 4.57, incl | 274 | 822 |
| Specified Diameter, mm | Stress at 1 % Extension, min, MPa | Ultimate Tensile Strength, min, MPa | Elongation in 250 mm, min, % | |||
| Class A | Class C | Class A | Class C | Class A | Class C | |
| 1.27 to 2.28, incl | 1310 | 1170 | 1450 | 1310 | 3.0 | 3.0 |
| 2.29 to 3.04, incl | 1280 | 1140 | 1410 | 1280 | 3.5 | 3.0 |
| 3.05 to 3.55, incl | 1240 | 1100 | 1410 | 1280 | 4.0 | 3.0 |
| 3.56 to 4.82, incl | 1170 | 1070 | 1380 | 1240 | 4.0 | 4.0 |
| Specified Diameter | Stress at 1 % Extension, min | Ultimate Tensile Strength, min | Elongation in 10 in. or 250 mm, | |||
| in. | mm | ksi | MPa | ksi | MPa | min % |
| 0.0500 to 0.0899, incl | 1.270 to 2.283, incl | 210 | 1450 | 235 | 1620 | 3.0 |
| 0.0900 to 0.1199, incl | 2.286 to 3.045, incl | 205 | 1410 | 230 | 1590 | 3.0 |
| 0.1200 to 0.1399, incl | 3.048 to 3.553, incl | 200 | 1380 | 225 | 1550 | 3.5 |
| 0.1400 to 0.1900, incl | 3.556 to 4.823, incl | 195 | 1340 | 220 | 1520 | 3.5 |
| Specified Diameter, mm | Stress at 1% Extension, | Ultimate Tensile Strength, | Elongation in 250 mm, min % |
| min, MPa | min, MPa | ||
| 1.27 to 2.28, incl | 1550 | 1825 | 3.0 |
| 2.29 to 3.04, incl | 1515 | 1790 | 3.0 |
| 3.05 to 3.55, incl | 1480 | 1760 | 3.5 |
| 3.56 to 4.82, incl | 1450 | 1725 | 3.5 |
| Specified Diameter, mm | Stress at 1% Extension, | Ultimate Tensile Strength, | Elongation in 250 mm, min % |
| min, MPa | min, MPa | ||
| 1.27 to 2.28, incl | 1580 | 1965 | 3.0 |
| 2.29 to 3.04, incl | 1550 | 1900 | 3.0 |
| 3.05 to 3.55, incl | 1515 | 1860 | 3.5 |
| 3.56 to 4.82, incl | 1480 | 1825 | 3.5 |
Scroll horizontally to review complete specification columns.
Request Full TDSZinc-5%Aluminum mischmetal alloy galvanized steel wire is used for Power Transmission and Distribution Line Hardware,Slope protection、Undersea optical cable armoured with low carbon galvanized steel wire,Overhead Electrical Conductors.
Product image and technical reference.