Technical Grade

CÂBLE D’INSTRUMENTATION

Instrumentation Cable are single or multi-pair/triple cables designed to carry signals.

CategoryOther Wire Cable
SourceDTC Cable

Product Images

Product Overview

Application

These single pair or triad instrumentation cables are constructed with heat and moisture resistant cross- linked polyethylene (XLPE) with an abrasion, oil, chemical and flame-resistant polyvinyl chloride (PVC), chlorinated polyethylene (CPE) or low smoke, zero halogen (LSZH/XLPO) jacket for use in utility substa- tion or power generation facilities. They are recomended for indoor or outdoor applica- tions in conduit, duct, cable tray or aerial installations and NEC-compliant for continuous operation at 90°C in wet and dry locations.

Features

  1. CONDUCTORS Class B, soft drawn, bare copper per ASTM B3 and ASTM B8.
  2. INSULATION Heat and moisture resistant, cross-linked polyethylene (XLP) meeting the requirements of NEMA WC57/ICEA S-73-532 and UL 66 &
  3. The insulation is suitable for use in wet or dry locations at a conductor temper- ature not exceeding 90°C for normal operation.
  4. CIRCUIT IDENTIfICATION One black and one white insulated single conductor in each pair with printed pair numbers (black/white/red for triads).
  5. PAIR ASSEMBLY Two insulated conductors twisted with a stranded tinned copper drain wire per ASTM B33 and wrapped with an aluminum foil/mylar shield and an isolation tape.
  6. CABLING Required number of pairs are cabled with non- hygroscopic fillers where necessary to form a round compact core.
  7. OVERALL SHIELD/DRAIN WIRE Helically applied aluminum foil/mylar tape. The drain is a stranded soft-drawn tinned copper per ASTM B33. Optional constructions include: Corrugated longitudinally-applied .005 or .008 copper shielding flat helically-applied .005 or .010 copper Longitunidally-applied copper or aluminum copolymer-bonded shield Copper braid (specify percentage of coverage for optimum EMI protection)
  8. JACKET Abrasion, oil and chemical resistant and highly flame retardant polyvinyl chloride (PVC), chlorinated poly- ethylene (CPE) or low smoke, zero halogen (LSZH/ XLPO) jacket to meet UL Standard
  9. Ratings UL Sunlight Resistant Oil resistant Optional Constructions Tinned copper conductors flexible stranded conductors PVC/Nylon or EPR insulation PVC, CPE, LSZH and XLPO jacket compounds 300 volt rating

Technical Parameters

Specification Table 1

Conductor AWGPair/Triad CountConductor Strand Class/ StrandingNominal Insulation Thickness in (mm)Nominal Jacket Thickness in (mm)Nominal Cable O.D. in (mm)Approximate Cable Weight Lbs/Mft (Kg/Km)
18 AWG1 pairB / 70.030 (0.8)0.045 (1.1)0.320 (8.2)49 (73)
18 AWG2 pairB / 70.030 (0.8)0.045 (1.1)0.490 (12.5)128 (190)
18 AWG4 pairB / 70.030 (0.8)0.060 (1.5)0.680 (17.3)190 (283)
18 AWG8 pairB / 70.030 (0.8)0.060 (1.5)0.810 (20.7)332 (494)
MORE
18 AWG12 pairB / 70.030 (0.8)0.080 (2.0)0.960 (24.5)486 (723)
18 AWG16 pairB / 70.030 (0.8)0.080 (2.0)1.090 (27.8)605 (900)
18 AWG24 pairB / 70.030 (0.8)0.080 (2.0)1.430 (36.5)960 (1428)
18 AWG1 triadB / 70.030 (0.8)0.045 (1.1)0.330 (8.4)60 (89)
18 AWG2 triadB / 70.030 (0.8)0.045 (1.1)0.550 (14.0)152 (226)
18 AWG4 triadB / 70.030 (0.8)0.060 (1.5)0.720 (18.4)261 (388)
18 AWG8 triadB / 70.030 (0.8)0.080 (2.0)0.920 (23.5)454 (676)
18 AWG12 triadB / 70.030 (0.8)0.080 (2.0)1.110 (28.3)627 (933)
18 AWG16 triadB / 70.030 (0.8)0.080 (2.0)1.150 (29.3)771 (1147)
18 AWG24 triadB / 70.030 (0.8)0.080 (2.0)1.530 (39.0)1218 (1812)
16 AWG1 pairB / 70.030 (0.8)0.045 (1.1)0.340 (8.7)62 (92)
16 AWG2 pairB / 70.030 (0.8)0.045 (1.1)0.540 (13.8)153 (228)
16 AWG4 pairB / 70.030 (0.8)0.060 (1.5)0.670 (17.1)255 (379)
16 AWG8 pairB / 70.030 (0.8)0.060 (1.5)0.850 (21.7)408 (607)
16 AWG12 pairB / 70.030 (0.8)0.080 (2.0)1.060 (27.0)610 (908)
16 AWG16 pairB / 70.030 (0.8)0.080 (2.0)1.230 (31.4)770 (1146)
16 AWG24 pairB / 70.030 (0.8)0.080 (2.0)1.380 (35.2)1175 (1748)
16 AWG1 triadB / 70.030 (0.8)0.045 (1.1)0.370 (9.4)78 (116)
16 AWG2 triadB / 70.030 (0.8)0.060 (1.5)0.630 (16.1)209 (311)
16 AWG4 triadB / 70.030 (0.8)0.060 (1.5)0.740 (18.9)349 (519)
16 AWG8 triadB / 70.030 (0.8)0.080 (2.0)1.030 (26.3)575 (856)
16 AWG12 triadB / 70.030 (0.8)0.080 (2.0)1.220 (31.1)803 (1195)
16 AWG16 triadB / 70.030 (0.8)0.080 (2.0)1.360 (34.7)1010 (1503)
16 AWG24 triadB / 70.030 (0.8)0.080 (2.0)1.590 (40.6)1549 (2305)

Scroll horizontally to review complete specification columns.

Request Full TDS

Structure & Technical Illustration

CÂBLE D’INSTRUMENTATION

Instrumentation Cable are single or multi-pair/triple cables designed to carry signals.

Product image and technical reference.

Related Products

FIL POUR BÂTIMENT

FIL POUR BÂTIMENT

View Details
CONDUCTEUR DE MISE À LA TERRE

CONDUCTEUR DE MISE À LA TERRE

View Details
CÂBLE DE COMMANDE MULTICONDUCTEUR ARMÉ

CÂBLE DE COMMANDE MULTICONDUCTEUR ARMÉ

View Details
EPR ISOLÉ CÂBLE

EPR ISOLÉ CÂBLE

View Details
INSTRUMENT CABLE | DTC Cable