Product Overview

APPLICATIONS

These cables are intended for fixed installations, indoors and outdoors, in low voltage control systems. They are normally used for connecting signaling and control units in industry, in railways, in traffic signals, in power or switching stations, as well as in switchgears, in applications where there is no risk of mechanical damage.

APPLICABLE STANDARDS

Low Voltage control cables are designed and tested to meet all the requirements of the latest edition of IEC 60502-1 standard. In addition, can also supply a range of alternative designs to meet customer-specified requirements.

Technical Parameters

0.6/1 kV CU/PVC/PVC Control cables, PVC insulated, unarmoured with copper conductor IEC 60502-1

No. of cores X Nominal cross sectional areaELECTRICAL DATADIMENSIONS AND WEIGHTS
Max. Conductor ResistanceContinuous Current RatingsApprox. overall diameterApprox. overall weight
DC at 20 °CAC at 70 °CLaid in groundLaid in ductsLaid in free air
mm²Ω / kmΩ / kmAAAmmkg / km
1.5 mm2
2 X 1.512.100014.47772719219.9145
MORE
3 X 1.512.100014.477723151810.4170
4 X 1.512.100014.477723151811.3205
5 X 1.512.100014.477717121412.6220
7 X 1.512.100014.477715101213.7275
10 X 1.512.100014.47771391116.9375
12 X 1.512.100014.47771281017.4425
14 X 1.512.100014.47771181018.2480
16 X 1.512.100014.47771181019.4545
19 X 1.512.100014.4777107920.4620
24 X 1.512.100014.477797923.6765
30 X 1.512.100014.477786824.9920
37 X 1.512.100014.477776727.11105
40 X 1.512.100014.477775728.21195
48 X 1.512.100014.477775731.01410
2.5 mm2
2 X 2.57.41008.866136242810.8185
3 X 2.57.41008.866129202311.4220
4 X 2.57.41008.866129202312.3265
5 X 2.57.41008.866122151813.9290
7 X 2.57.41008.866119131614.9360
10 X 2.57.41008.866117121518.5495
12 X 2.57.41008.866116111419.1570
14 X 2.57.41008.866115101320.0645
16 X 2.57.41008.866114101321.3735
19 X 2.57.41008.86611391222.4840
24 X 2.57.41008.86611291126.01045
30 X 2.57.41008.86611181027.51260
37 X 2.57.41008.86611071029.91525
40 X 2.57.41008.8661971031.31660
48 X 2.57.41008.866197934.51975
4.0 mm2
2 X 4.04.61005.515947323812.7260
3 X 4.04.61005.515938263213.4315
4 X 4.04.61005.515938263214.6385
5 X 4.04.61005.515929212516.4420
7 X 4.04.61005.515925182217.9535
10 X 4.04.61005.515922162022.5740
12 X 4.04.61005.515920151923.2860
14 X 4.04.61005.515919141824.4980
16 X 4.04.61005.515918131726.01120
19 X 4.04.61005.515917121627.41285
24 X 4.04.61005.515915121632.21620
30 X 4.04.61005.515914111434.31990
37 X 4.04.61005.515913101337.52430
40 X 4.04.61005.51591291339.02620
48 X 4.04.61005.51591191343.03115

0.6/1 kV CU/ PVC/CT SHIELDED/PVC Control cables, PVC insulated, copper tape shielded with copper conductor IEC 60502-1

No. of cores X Nominal cross sectional areaELECTRICAL DATADIMENSIONS AND WEIGHTS
Max. Conductor ResistanceContinuous Current RatingsApprox. overall diameterApprox. overall weight
DC at 20 °CAC at 70 °CLaid in groundLaid in ductsLaid in free air
mm²Ω / kmΩ / kmAAAmmkg / km
1.5 mm2
2 X 1.512.100014.477727192212.2225
MORE
3 X 1.512.100014.477722151812.8255
4 X 1.512.100014.477722151813.6290
5 X 1.512.100014.477716121415.0315
7 X 1.512.100014.477714101216.0380
10 X 1.512.100014.47771391119.2500
12 X 1.512.100014.47771291019.7555
14 X 1.512.100014.47771181020.5615
16 X 1.512.100014.4777108921.7690
19 X 1.512.100014.4777107922.7770
24 X 1.512.100014.477797825.9940
30 X 1.512.100014.477786827.21105
37 X 1.512.100014.477775729.41305
40 X 1.512.100014.477775730.51405
48 X 1.512.100014.477775733.31645
2.5 mm2
2 X 2.57.41008.866135252913.1270
3 X 2.57.41008.866129202413.7310
4 X 2.57.41008.866129202414.7360
5 X 2.57.41008.866121161816.1385
7 X 2.57.41008.866119141617.2475
10 X 2.57.41008.866116121520.8635
12 X 2.57.41008.866115111421.4715
14 X 2.57.41008.866114101322.3795
16 X 2.57.41008.866113101323.6895
19 X 2.57.41008.86611291224.71005
24 X 2.57.41008.86611191128.31245
30 X 2.57.41008.86611081029.81465
37 X 2.57.41008.8661971032.41765
40 X 2.57.41008.866197933.61895
48 X 2.57.41008.866187937.22265
4.0 mm2
2 X 4.04.61005.515945333915.0360
3 X 4.04.61005.515937273215.8420
4 X 4.04.61005.515937273216.9500
5 X 4.04.61005.515928212518.8535
7 X 4.04.61005.515924182220.2670
10 X 4.04.61005.515921162024.8910
12 X 4.04.61005.515920151925.51035
14 X 4.04.61005.515919141826.71165
16 X 4.04.61005.515918131728.31315
19 X 4.04.61005.515916121629.71490
24 X 4.04.61005.515915121534.91895
30 X 4.04.61005.515913111437.02280
37 X 4.04.61005.515912101339.52695
40 X 4.04.61005.51591291341.72950
48 X 4.04.61005.51591191245.93500

0.6/1 kV CU/PVC/SWA/PVC Control cables, PVC insulated, wire armoured with copper conductor IEC 60502-1

No. of cores X Nominal cross sectional areaELECTRICAL DATADIMENSIONS AND WEIGHTS
Max. Conductor ResistanceContinuous Current RatingsApprox. overall diameterApprox. overall weight
DC at 20 °CAC at 70 °CLaid in groundLaid in ductsLaid in free air
mm²Ω / kmΩ / kmAAAmmkg / km
1.5 mm2
2 X 1.512.100014.477727202313.5365
MORE
3 X 1.512.100014.477722161914.0400
4 X 1.512.100014.477722161914.9450
5 X 1.512.100014.477717121416.2495
7 X 1.512.100014.477715111317.3575
10 X 1.512.100014.477713101221.9870
12 X 1.512.100014.47771291122.4945
14 X 1.512.100014.47771181023.21015
16 X 1.512.100014.47771081024.41115
19 X 1.512.100014.4777107926.11365
24 X 1.512.100014.477797929.31630
30 X 1.512.100014.477786830.61820
37 X 1.512.100014.477776733.02105
40 X 1.512.100014.477776734.12235
48 X 1.512.100014.477775737.22830
2.5 mm2
2 X 2.57.41008.866135253014.4420
3 X 2.57.41008.866129212515.0470
4 X 2.57.41008.866129212515.9530
5 X 2.57.41008.866122161917.5590
7 X 2.57.41008.866119141719.9805
10 X 2.57.41008.866117121523.51045
12 X 2.57.41008.866115121424.11130
14 X 2.57.41008.866114111425.71375
16 X 2.57.41008.866114101327.01520
19 X 2.57.41008.866113101228.11665
24 X 2.57.41008.86611291231.92005
30 X 2.57.41008.86611081133.42280
37 X 2.57.41008.86611071036.02645
40 X 2.57.41008.8661971037.53110
48 X 2.57.41008.866197941.13585
4.0 mm2
2 X 4.04.61005.515946344016.3535
3 X 4.04.61005.515938273417.9725
4 X 4.04.61005.515938273419.1820
5 X 4.04.61005.515928212620.9905
7 X 4.04.61005.515925192322.91070
10 X 4.04.61005.515922172128.21570
12 X 4.04.61005.515920152028.91705
14 X 4.04.61005.515919141930.11870
16 X 4.04.61005.515918141831.72065
19 X 4.04.61005.515917131733.32290
24 X 4.04.61005.515915121639.03155
30 X 4.04.61005.515914111440.93600
37 X 4.04.61005.515912101343.44100
40 X 4.04.61005.515912101345.84450
48 X 4.04.61005.51591191250.05475

Scroll horizontally to review complete specification columns.

Request Full TDS

Structure & Technical Illustration

0.6/1 kV Control cables, PVC insulated with copper conductor

Control cables are normally used for connecting signaling and control units in industry, in railways, in traffic signals, in power or switching stations LEAVE MESSAGE SEND E-MAIL

Product image and technical reference.

Related Products

LT & HT POWER CABLE

LT & HT POWER CABLE

View Details
Flame retardant and fire resistant cable

Flame retardant and fire resistant cable

View Details
LV MV Power cable

LV MV Power cable

View Details
600/1000 V XLPE insulated, wire armoured with copper conductor BS 5467

600/1000 V XLPE insulated, wire armoured with copper conductor BS 5467

View Details