Technical Grade
INDOOR OPTICAL FIBER CABLE

INDOOR OPTICAL FIBER CABLE

Indoor Fiber Optic Cables are used exclusively within buildings and must have a flame-retardant jacket to fit this purpose. LEAVE MESSAGE SEND E-MAIL

CategoryOptical Fiber Cable
SourceQZ Cable Group

Product Images

Product Overview

Indoor Fiber Optic Cables are used exclusively within buildings and must have a flame-retardant jacket to fit this purpose. LEAVE MESSAGE SEND E-MAIL

Technical Parameters

Specification Table 1

Fiber CountsCable Diamter(mm)Weight (kg/km)Tensile strength(N)Crush Resistance(N/100mm)Minimum bending radius (mm)
Short-termLong-termShort-termLong-termStaticDynamic
22.5*3.57.3200805002003050
42.5*3.57.4200805002003050
62.5*4.08.2200805002003050
82.5*4.59.3200805002003050
MORE
122.5*5.010200805002003050

Specification Table 2

Cable Diamter (mm)Tight Buffer diameter (mm)Weight (kg/km)Tensile strength(N)Crush ResistanceMinimum bending radius (mm)
Short-termLong-termShort-termLong-termStaticDynamic
1.60.62.81508050010020D10D
1.80.63.01508050010020D10D
2.00.94.251508050010020D10D
2.40.95.001508050010020D10D
MORE
2.80.96.601508050010020D10D
3.00.97.001508050010020D10D

Specification Table 3

Cable Diameter(mm)Inner Jacket diameter(mm)Weight(kg/km)Tensile strength(N)Crush Resistance(N/100mm)Minimum bending radius (mm))
Short-termLong-termShort-termLong-termStaticDynamic
3.0*5.01.85630080010005006030
3.2*5.626530080010005006030
4.0*7.038830080010005006030

Specification Table 4

Fiber CountsCable Diamter(mm)WeightTensile strength(N)Crush Resistance(N/100mm)Minimum bending radius (mm)
Short-termLong-termShort-termLong-termStaticDynamic
2415.5±0.42051500500150060010D20D
3617.5±0.42551500500150060010D20D
4817.5±0.42551500500150060010D20D
7219.5±0.43201500500150060010D20D
MORE
9622.0±0.43951500500150060010D20D
14428.0±0.45791500500150060010D20D

Specification Table 5

Fiber CountsCable Diamter(mm)WeightTensile strength(N)Crush Resistance(N/100mm)Minimum bending radius (mm)
Short-termLong-termShort-termLong-termStaticDynamic
45.2±0.416.213044010003006030
65.5±0.42013044010003006030
86.2±0.42613044010003006030
126.5±0.431.520066010003006030
MORE
248.2±0.450.520066010003006030
369.0±0.470.520066010003006030
4810.5±0.488.520066010003006030

Scroll horizontally to review complete specification columns.

Request Full TDS

Structure & Technical Illustration

INDOOR OPTICAL FIBER CABLE

Indoor Fiber Optic Cables are used exclusively within buildings and must have a flame-retardant jacket to fit this purpose. LEAVE MESSAGE SEND E-MAIL

Product image and technical reference.

Related Products

OUTERDOOR OPTICAL FIBER CABLE

OUTERDOOR OPTICAL FIBER CABLE

View Details
ADSS OPTICAL FIBER CABLE

ADSS OPTICAL FIBER CABLE

View Details
OPGW OVERHEAD GROUND WIRE

OPGW OVERHEAD GROUND WIRE

View Details
OPPC OPTICAL PHASE CONDUCTOR

OPPC OPTICAL PHASE CONDUCTOR

View Details